Gtco Surface-Lit AccuTab - Users Guide Manuel d'utilisateur Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
Surface-Lit AccuTab 42
Turn Status Indicator or Cursor Illumination On
Tone Status Indicator or Cursor Illumination Off
Code: ON
Code: OF
These commands control the state of the yellow status indicator on the 16-button cursor or
the cursor lamps on the illuminated cursor.
Diagnostic Commands
Transmit Version Number
Code: VR
Command causes AccuTab to determine and transmit the version number of the firmware
currently installed.
Display Tablet Active Area Size
Code: SZ
AccuTab automatically determines the size of the attached tablet’s active area when it is
turned on or reset. This command can be used to send the information to another device.
The size is encoded as four digits: two digits representing vertical size in inches followed by
two digits representing horizontal size in inches. For example, the 36” x 48” AccuTab sends
the digits 3648 in response to this command.
Read Tablet Diodes
Code: RD
Diagnostic command causes the AccuTab to examine the attached tablet and send the
results to another device for display. A “1” means a diode is present and a “0” means a
diode is missing.