Cordless Roll-Up 1 Table of Contents Standard Operating Information Parts Checklist Introduction What You Need to Use Cordless Rol
Cordless Roll-Up 10 the coil wires do not get pinched between the housing and base. 6. Snap the unit together, making sure that the battery
Cordless Roll-Up 11 Changing the Tablet’s Orientation The Cordless Roll-Up allows the user to choose between two different tablet orientation
Cordless Roll-Up 12 Table 1: SuperSet Menu Codes for Selected Application Programs
Cordless Roll-Up 13
Cordless Roll-Up 14
Cordless Roll-Up 15
Cordless Roll-Up 16
Cordless Roll-Up 17 Table 2: Configuration Details for SuperSet Menu Codes NOTE: MAX = 140 coordinates/second lpi = lines per inch lp
Cordless Roll-Up 18
Cordless Roll-Up 19 Example: Configuring for Specific Application Programs To configure the Cordless Roll-Up to operate with Autodesk’s Aut
Cordless Roll-Up 2 Remote Commands GTCO Cordless Roll-Up Command Summary Functional Control Commands
Cordless Roll-Up 20 3. Choose on the SuperSet Menu. This enters the first digit of the SuperSet code for AutoCAD. 4. Select on the Su
Cordless Roll-Up 21 Configurations set up can be stored in any of ten user-definable SuperSet locations (codes 90 through 99) for recall at a
Cordless Roll-Up 22 7. After making your selections, you can save the configuration as a temporary configuration or save the configuration i
Cordless Roll-Up 23 Custom Configuration Menu Storage Replacing a Lost Menu Card If you lose the menu card provided with the Cordless Roll-U
Cordless Roll-Up 24
Cordless Roll-Up 25 Communication Options Baud: The rate, in bits/second, at which characters are transmitted across the RS-232C serial in
Cordless Roll-Up 26 Space: Defines whether the Space (Sp) character (hex 20) is included in the ASCII output report as a delimiter between
Cordless Roll-Up 27 Resetting the Cordless Roll-Up There are three ways to reset the Cordless Roll-Up: Enter SuperSet code 00 Unplug an
Cordless Roll-Up 28 Battery low indicates that the battery in the transducer should be replaced. The system is designed to continue opera
Cordless Roll-Up 29 Procedure A: Begin Troubleshooting
Cordless Roll-Up 3 Standard Operating Information Parts Checklist Cordless Roll-Up digitizing tablet Transducer (stylus or 4-button cur
Cordless Roll-Up 30 Procedure B: Troubleshooting
Cordless Roll-Up 31 Procedure C: Troubleshooting
Cordless Roll-Up 32 Using GTCOTEST GTCOTEST is a program that runs on the PC. It can be used to perform communication and diagnostic tests o
Cordless Roll-Up 33 9. If GTCOTEST indicates that the digitizer is functioning properly, check your software application setup and SuperSet
Cordless Roll-Up 34 Figure 3: Power Supply Connector Figure 4: RS-232C Interface
Cordless Roll-Up 35 Figure 5: 9- to 25-Pin Adapter Advanced Operating Information Cordless Roll-Up Interfacing The following information is
Cordless Roll-Up 36 This section provides basic information about RS-232C communications. There are three areas to consider when using RS-23
Cordless Roll-Up 37 Flow Control Flow control is the process of regulating the traffic or flow of data between two RS-232C devices. Flow con
Cordless Roll-Up 38 The Cordless Roll-Up responds to three kinds of commands: GTCO Cordless Roll-Up Standard Commands (with some omissions
Cordless Roll-Up 39 Functional Control Commands Reset Code: RS The Reset command will reset the Controller to the last known configurat
Cordless Roll-Up 4 Special features include: Cordless transducers Flexible, portable tablet Dual tablet orientation GTCO, CalComp
Cordless Roll-Up 40 Read Current Coordinate Code: hex 02 (Ctrl-B) The Read Current Coordinate causes the Cordless Roll-Up to output a
Cordless Roll-Up 41 Set Digitizing Rate Code: Rx Coordinates can be sent from the Cordless Roll-Up at rates from 5 to 140 coordinates per sec
Cordless Roll-Up 42 Format Selection Commands ASCII Format Output Code: AS Command causes coordinates to be transmitted in ASCII. ASCII coor
Cordless Roll-Up 43 Format Selection Commands, Cont. Pushbutton Include Pushbutton Exclude Code: PI Code: PE Space Include Space Exclude Co
Cordless Roll-Up 44 Diagnostic Commands Transmit Version Number Code: VR Command causes Cordless Roll-Up to determine and transmit the versio
Cordless Roll-Up 45 CalComp Emulation Commands The Cordless Roll-Up recognizes a subset of the CalComp 9500 command set. Space does not perm
Cordless Roll-Up 46
Cordless Roll-Up 47 Summagraphics Emulation Commands The Cordless Roll-Up recognizes a subset of the Summagraphics UIOF command set. Space
Cordless Roll-Up 48
Cordless Roll-Up 49 Command Mode Basics To enter GTCO CalComp by Turning Technologies Command Mode: Send an ASCII CTRL-A (hex 01) character
Cordless Roll-Up 5 1. Disconnect the transducer and interface cable from the Cordless Roll-Up and the computer. Remove all material from th
Cordless Roll-Up 50 Cordless Roll-Up sends a “>” (hex 3E) as a prompt to the commanding device. The Cordless Roll-Up is now ready to a
Cordless Roll-Up 51 2. Send the command one character at a time. The Controller will respond by echoing each character. Waiting for the c
Cordless Roll-Up 52 Advanced Programming Information NOTE: The following information is not required for normal Cordless Roll-Up operation. I
Cordless Roll-Up 53 hand, binary formats cannot be directly displayed on a terminal or printed-they must be converted first into displayable
Cordless Roll-Up 54 Table 4: GTCO/CalComp High Resolution Binary Format To set up the GTCO/CalComp Binary Format: Custom Configuration Menu:
Cordless Roll-Up 55 Summagraphics Binary Format This eight-byte format is compatible with the Summagraphics 2000 lpi UIOF format. Table 5 sh
Cordless Roll-Up 56 Low Resolution Binary Format Low resolution binary format conforms to an existing industry standard method of encoding sm
Cordless Roll-Up 57 Binary formats include five bits which encode the button. The bits transmitted in the format depend on the button presse
Cordless Roll-Up 58 ASCII Formats ASCII is a commonly used method for encoding text. ASCII coordinate formats can be directly displayed on m
Cordless Roll-Up 59 To include a Cursor Button Code, Space, Decimal Point or Line Feed in an ASCII Format (where permitted): Custom Configura
Cordless Roll-Up 6 2. Remove the Cordless Roll-Up from its container and unroll it on the selected surface. 3. Plug the power supply into
Cordless Roll-Up 60 Table 10: CalComp ASCII Formats Table 11: Summagraphics ASCII Formats Cursor Button Codes in ASCII Formats When the cu
Cordless Roll-Up 61 Measurement Scales You can choose either English or metric scaling for the coordinates you digitize. Cordless Roll-Up ap
Cordless Roll-Up 62 Digitizing Modes Digitizing mode refers to the method Cordless Roll-Up uses to determine when to output a coordinate form
Cordless Roll-Up 63 Table 14: Results of Active Area and Pushbutton Changes in Digitizing Modes Point Mode In Point Mode, one coordinate is
Cordless Roll-Up 64 Line Mode In Line Mode, coordinates are sent as long as a transducer button is pressed. Output occurs only when the tran
Cordless Roll-Up 65 Line Incremental Mode In Line Incremental Mode, one coordinate is sent when the transducer is moved farther than a preset
Cordless Roll-Up 66 Remote Request Mode In Remote Request Mode, one coordinate is sent when the Controller receives a Read Current Coordinate
Cordless Roll-Up 67 Programming Example: To Read High Resolution Binary Formats 1. Configure the Cordless Roll-Up for 9600, N, 8, 1, GTCO Bi
Cordless Roll-Up 68 Programming Example: To Send Version Command and Display Results This QBASIC program interacts with the Cordless Roll-Up
Cordless Roll-Up 69 General Product Information Radio and Television Interference The user is cautioned that any changes or modifications not
Cordless Roll-Up 7 If an appropriate SuperSet Code is not listed in Table 2, use the Custom Configuration Menu to set up the Cordless Roll
Cordless Roll-Up 70 Bescheinigung des Herstellers/Importeurs Heirmit wird bescheinigt, dass der/die/das 3036R (Geraet, Typ, Bezeichnung) im U
Cordless Roll-Up 71 Limited Warranty for Cordless Roll-Up GTCO CalComp by Turning Technologies, Inc. warrants these products to be free from
Cordless Roll-Up 72 2. Costs for initial technical adjustments (setup), including adjustment of user controls. 3. Certain shipping charges.
Cordless Roll-Up 73 consequential damages. The price stated and paid for the equipment is a consideration in limiting GTCO CalComp by Turnin
Cordless Roll-Up 74 Corporate Headquarters 14557 N. 82nd Street Scottsdale, Arizona 85260 Tel: 1-866-746-3015 Support: 1-866-746-3015 Fax
Cordless Roll-Up 8 The stylus uses AAA batteries. Contact GTCO CalComp by Turning Technologies at 1.866.746.3015 for cursor batteries. (See
Cordless Roll-Up 9 NOTE: The lithium battery used in this device may present a fire, explosion and severe burn hazard if mistreated. Do not
Commentaires sur ces manuels