2500 Series 1 Table of Contents Commands Entering Commands Command Prefix Entering Commands from the 16-Button Cursor Entering Comman
2500 Series 10 Changing the Character Constants 9100 Formats Only The tablet transmits ASCII characters to represent Tablet Status, Mode Status, Pen
2500 Series 11 EXAMPLE: To change the Run mode character to the new character “&” and leave all others at their default values, enter the follow
2500 Series 12 Where a for the host or cursor can equal A or B. If a = A If a = B Command applies to Port A Command applies to Port B Where b can e
2500 Series 13 each byte frame. The table below shows the maximum usable data rates for the seven 2500 RS-232 output baud rates, based on a 19 char
2500 Series 14 Menu = [LINE FEED ON/OFF] [b] [CR] Where b can equal 0, 1 or no entry. If b = 0 If b = 1 If no b is entered Line Feed will be disab
2500 Series 15 To cancel prompting, enter: Host = ESC % Q CR Menu = [SET PROMPT] [CR] Messages and Indicators The operator may send messages to
2500 Series 16 Messages from the Cursor to the Host The digitizer stops output when the F-button is pressed. No data will be output until the E or
2500 Series 17 If b = 0 If b = 1 If b = 2 If b = 3 LED #2 will extinguish LED #2 will light LED #3 will extinguish LED #3 will light Controlling th
2500 Series 18 Where: (b1) = A, for Port A, B for Port B or no entry. b2 = baud rate code number 0 = 19200 1 = 9600 2 = 4800 3 = 2400 4 = 1200 5 = 6
2500 Series 19 Digitizing Commands The following commands are those you might use while digitizing. They include changing operating modes, data rat
2500 Series 2 Change Format Move Origin Enable/Disable Margin Data Create Window Aligning Media Using the Window Command En
2500 Series 20 NOTE: The increment distance must be set before you change the tablet to increment mode. If you set the increment distance, use Incre
2500 Series 21 Resolution When the transducer is placed on the active area of the tablet, the tablet calculates its X and Y position relative to the
2500 Series 22 The resolution of 50 lines per millimeter is the maximum specified metric resolution for the 9100 Digitizer. The coordinate pair is
2500 Series 23 Menu = [SYSTEM FUNC 1] [R] [2400] [,] [0] [CR] Change Format To change the operating format, use the below command: Host = ESC %
2500 Series 24 Enable/Disable Margin Data The margin is the remainder of the tablet surface surrounding the active area. Under default conditions,
2500 Series 25 Cancel Window: Host = ESC % J w CR (lowercase w) Menu = [SYSTEM FUNC 1] [w] [CR] (lowercase w) Where: <dpoint 1> <d
2500 Series 26 5. For dpoint 1, pick a point on the selected line as far to the left (for horizontal line) or bottom (for a vertical line) as possi
2500 Series 27 Where b can equal 0, 1 or no entry: If b = 0 If b = 1 If no b is entered Digitizer will transmit coordinate pairs whether the tr
2500 Series 28 If you have changed a parameter from its soft switch setting by using a host or menu command, it will NOT be saved by the command.
2500 Series 29 2000 Series Compatible Command Summary The 2000 series compatible commands are a single letter transmitted from the host. There is n
2500 Series 3 Commands The 2500 tablet can accept the command set of the CalComp 2000 series tablets as well as commands of the standard CalComp 910
2500 Series 30 16-Button Cursor Command Summary The 16-button cursor has a limited subset of the tablet commands. The FF serves as the command pref
2500 Series 31 Host and Menu 9100 Series Compatible Command Summary All host commands must be preceded by a command prefix and followed by CR. The
2500 Series 32
2500 Series 33
2500 Series 34
2500 Series 35
2500 Series 36 Basic Program to Check Installation The following program, written in MICROSOFT BASIC, will cause the IBM PC or compatible system to
2500 Series 37 ASCII Code Chart
2500 Series 38 2500 Menu Overlay
2500 Series 4 The 2500 commands will be explained in the following order: 1. Commands that control the command sources. 2. Commands that regulate
2500 Series 5 F F a b (b) N E F button pressed twice is the command prefix Single button code for the command Any required parameter of the comman
2500 Series 6 The command will take effect as soon as the Carriage Return block is picked. NOTE: Picking the [ESC] [%] blocks from the ASCII portio
2500 Series 7 Where: b1 b2 b3 First command prefix character Second, optional, command prefix character Third, optional, command prefix character
2500 Series 8 Where b can equal 0 or 1 or no entry: If b = 0 If b = 1 If no b is entered BANK and SELECT blocks are enabled. BANK and SELECT blocks
2500 Series 9 Using the Soft Switches to Control the Menu Three of the switches in bank seven are dedicated to a three-choice menu that may be used